I am a qualified NICEIC registered Electrician with over 34 years in the industry, undertaking all electrical works to a high standard, and a member of Electrical Safety Register.

A last minute job for my mate Lee Murray and his company Murray decorators, his customer needed cables in her living roo...
05/06/2026

A last minute job for my mate Lee Murray and his company Murray decorators, his customer needed cables in her living room to be removed and put in neater to the socket, after lifting the floorboard and re - diverting the cables behind the skirting board to the socket.

So, Lee and his team can undertake the decorating this weekend.

Customer very happy.

A customer of mine Darren and Kristy from a couple of years ago wanted me to quote on installing shed electrics last yea...
22/04/2026

A customer of mine Darren and Kristy from a couple of years ago wanted me to quote on installing shed electrics last year, but after a set back they got a hot tub installed and needing electrics for this and a barbecue, after assessing the set up and being informed of the power consumption, their electrics under the stairs has a couple of consumer units with no capacity, so I advised them to have a new board which consists of a main switch, a SPD ( Surge Protection Device ) and a circuit breaker, so that if any issues occur, this wouldn't affect the house, and this was mounted on two pieces of batten wood and the board mounted on this.

Whilst installing a new board, a new 6mm armoured cable was installed, clipped around the wall, across the pathway, and laid into the garden, around the hot tub enclosure, and into the shed.

The new garage consumer unit with RCD ( Residual Citcuit Device ) had two circuit breakers, one for the external socket for the hot tub and internal socket for power tools and another one for the barbecue, all having plastic tube to protect the cables.

After three days, finally completed and working.

One of my existing customers Chris and Katie asked me to quote and install new electrics to their garage as they were ge...
17/04/2026

One of my existing customers Chris and Katie asked me to quote and install new electrics to their garage as they were getting a new electric vehicle charging point, however, due to the company asking for a very specific electrics to be installed, I carried out a new 6mm armoured cable from the main consumer unit, around the wall at the top, and into their garage.

With a new garage consumer unit with RCD and one circuit breaker for the EV charger, and one for normal use inside the garage.

Just to return next week to finish off clipping and certification as its a new installation, with certification to them and notification to the local authority.

I went to a job to quote in September last year to get two garden lanterns working, as the weather has been against me d...
24/03/2026

I went to a job to quote in September last year to get two garden lanterns working, as the weather has been against me doing this, today I went back to undertake this.

The new lanterns in place, assessing the wiring, it had wiring used for indoors only, and the tubing that had the cables in them were in bad way.

So with a new weatherproof box for all the connections, I install a cable called ' HO 5 ' with plastic flexible tube to contain the cable in and a switch fused spur to operate this.

A couple of weeks ago, I went to a new customer Maureen and Chris from Belvedere, ( recommended by their daughter who is...
23/03/2026

A couple of weeks ago, I went to a new customer Maureen and Chris from Belvedere, ( recommended by their daughter who is a previous customer ) has they have just bought a property and realised that not many sockets were in there, so asked me to quote for additional sockets and to be chased in the wall, along with a outdoor socket.

Returning back next week to install one socket for the TV in the bedroom.

One of my existing customers Sam from Thamesmead, called me up around a month ago as there was no lights working on both...
19/03/2026

One of my existing customers Sam from Thamesmead, called me up around a month ago as there was no lights working on both upstairs and downstairs, so I attended and the fuse board had broken the rewireable fuse, so I changed the rewireable fuse to a circuit breaker allowing her to reset it without threading a piece of fuse wire.

With the lights back on, I highly recommended a new board, but before that was done, I mentioned a EICR ( Electrical Installation Condition Report ) which I would go around to the sockets, lights, switches and all electrical accessories and check the wiring and the condition of the accessories.

Once this is done, and noted on my portal, a report with a quotation was sent, as the lights in porch and bathroom did not comply with regulations.

Yesterday, I carried out the removal of the old fuse board and installed one with RCDs and SPD ( Surge Protection Device ) and removed the meter tails and installed new ones due to the overall power consumption.

Took meter readings and certification would be sent along with a building control certificate from the local authority.

A new customer in Mottingham, recently got in touch with me about their fuse board, and asked me to quote for a new one,...
12/03/2026

A new customer in Mottingham, recently got in touch with me about their fuse board, and asked me to quote for a new one, as this had no protection against faults on circuits and made of plastic with a wooden structure.

So, I recommended a full electrical report on the property to see if any other issues would be identified, and send them a quotation.

Today, I returned with signing the board off and a ' unsatisfactory ' and ' satisfactory ' report with a few additional extras to complete it.

Today, after a previous visit to a new customer, the bathroom fan wasn't working, so I quoted a new fan, after removing ...
28/01/2026

Today, after a previous visit to a new customer, the bathroom fan wasn't working, so I quoted a new fan, after removing the existing fan, it turns out that the electronic components had seized up, so installed a basic one.

Left all working.

One of my customers Andrew of Sidcup, who has been my customer for over three years, ask me to quote for a new installat...
27/01/2026

One of my customers Andrew of Sidcup, who has been my customer for over three years, ask me to quote for a new installation for his cabin.

Having inspected the cabin and what he would like, he said three sockets, light switch and light, but because of his main board in the house, wasn't compatible and needed a new consumer unit with protection, so this was upgraded firstly.

Then today I completed the install, with a 4mm armoured cable from the main board ( circuit breaker for this cabin, but connected to the main switch, so if any issues from the cabin, will not affect the house ) and with a garage unit feeding lights and sockets.

Yesterday and today I under took a full cabin Installation for a existing customer in Blackfen with 3 double sockets, 1 ...
14/01/2026

Yesterday and today I under took a full cabin Installation for a existing customer in Blackfen with 3 double sockets, 1 x light with light switch and a garage unit with RCD protection.

All cables in mini trunking, with a armoured cable from the house down the garden.

Returning to connect both ends.