Borneo Quality & Living

Borneo Quality & Living By Borneo Quality Enterprise | Kuching-based | New Property Defect Inspection & Rental Room Services

Defect:Unsheathed single-core electrical cables are hanging exposed from the circular conduit junction box without prope...
06/09/2026

Defect:
Unsheathed single-core electrical cables are hanging exposed from the circular conduit junction box without proper conduit enclosure, support, or cover plate.

Potential Risks / Consequences:

Electric shock hazard: Exposed electrical cables may come into contact with people or conductive surfaces.

Short-circuit and fire risk: Unprotected cables are more susceptible to mechanical damage, moisture, and insulation deterioration.

Cable damage: Unsupported hanging cables may place stress on the cable connections and terminals.

Moisture and dust ingress: The absence of a proper cover plate may allow dust and moisture to enter the junction box.

05/09/2026

A misaligned floor trap may look like a tiny finishing issue, but it can contribute to water ponding, unpleasant odours, drainage problems and even a tripping hazard.

The rule is simple: small defect today, bigger headache tomorrow. 🏠💧

🔎 Check it before you move in.

📍 Kuching, Sarawak
🎉 Follow our page and enjoy 10% OFF your defect inspection!

WE CHECK. YOU RELAX.

05/09/2026

Just got the keys to your new home? Don’t know how to check for defects in your house?

Don’t worry! We’re here to help. This is your opportunity to claim warranty from the developer without having to pay for the repair costs.

Contact us now to get your FREE quotation!
Whatapps: 013-668 1106

That tiny gap around your socket may look harmless. But should it be there? 👀A poorly fitted faceplate can mean poor wor...
05/09/2026

That tiny gap around your socket may look harmless.

But should it be there? 👀

A poorly fitted faceplate can mean poor workmanship, loose mounting, moisture or even exposed wiring risks.

Don’t wait for a small defect to become a bigger problem.

🔎 Spot it. Check it. Fix it.

📍 Kuching, Sarawak
🎉 Follow our page and enjoy 10% OFF your defect inspection!

🛡️ WE CHECK. YOU RELAX.

🚪 That little gap around your ceiling access panel? Don’t ignore it. 👀It may look minor, but poor sealing can allow dust...
04/09/2026

🚪 That little gap around your ceiling access panel? Don’t ignore it. 👀

It may look minor, but poor sealing can allow dust, insects, moisture and unwanted air leakage into your ceiling space.

Small gap. Bigger problem. Catch it before it gets worse.

📍 Kuching, Sarawak
🎉 Follow our page and enjoy 10% OFF your defect inspection!

WE CHECK. YOU RELAX.

Waterproofing failure often stays invisible until water starts seeping into walls, ceilings or floors. By then, a small ...
03/09/2026

Waterproofing failure often stays invisible until water starts seeping into walls, ceilings or floors. By then, a small hidden defect may have already become a costly repair. 💸

🔎 Don’t wait for stains or leaks. Inspect early and protect your home.

📍 Kuching, Sarawak
🎉 Follow our page and enjoy 10% OFF your defect inspection!

WE CHECK. YOU RELAX.

Some cracks are purely cosmetic. Others may be linked to movement, moisture, poor workmanship or more serious underlying...
03/09/2026

Some cracks are purely cosmetic. Others may be linked to movement, moisture, poor workmanship or more serious underlying issues. The real danger is not seeing the crack, it's ignoring what caused it.

🔎 Spot defects early. Fix them before they grow into expensive problems.

📍 Kuching, Sarawak
🎉 Follow our page and enjoy 10% OFF your defect inspection!

🛡️ WE CHECK. YOU RELAX.

Mould and mildew often signal hidden moisture, water leakage, or poor ventilation. Ignore it today, and you could be fac...
02/09/2026

Mould and mildew often signal hidden moisture, water leakage, or poor ventilation. Ignore it today, and you could be facing damaged finishes, unpleasant odours and costly repairs tomorrow. 💸🏠

🔎 Don’t just clean the mould. Find the cause.

📍 Kuching, Sarawak
Follow our page and enjoy 10% OFF your defect inspection!

🛡️ WE CHECK. YOU RELAX.

02/09/2026

扶手墙的周边未施作硅胶密封,可能导致水分渗入缝隙。

Handrail wall fl**ge base 未使用 silicone sealant 的坏处:

💧 容易渗水:水分可能从法兰底座与墙面之间的缝隙渗入。

🦠 导致潮湿和发霉:长期受潮可能造成墙面出现霉菌或水渍。

🔩 金属部件生锈:水分进入后,可能导致固定螺丝或金属底座腐蚀、生锈。

🧱 影响墙体耐久性:长期渗水可能导致墙面材料劣化或出现损坏。

29/08/2026

窗扇在开启和关闭时出现明显的机械摩擦和卡滞现象,并伴有较大的刺耳异响。

这个现象可能带来的坏处:

影响正常使用:窗扇开启和关闭困难,操作不顺畅。

加速零件磨损:长期摩擦可能导致滑轮、铰链、轨道等部件过早损坏。

可能造成窗扇损坏:持续卡滞或强行操作,可能导致窗框、五金件变形或松动。

存在安全隐患:紧急情况下可能无法快速开启或关闭窗户。

噪音问题:刺耳异响影响居住舒适度。

可能导致问题恶化:若由安装不当、窗扇错位或五金件故障引起,长期不维修可能增加后续维修成本。