10/17/2025
Farm Inspection from a while back! This was a fun one to do.
A few highlights:
1. The chimney needed some repointing done, and also the flashing was just roofing tar. This is improper. Both of these things can lead to water entry in around the flue, or in the attic space respectively.
2. Some deck boards that were a bit bouncy, due to supports being too far spaced out. In construction, many different sized boards are used on a home. The support spacing needed for these boards decreases as the board gets smaller. Proper concrete footings and posts should be used when building a deck.
3. This photo is of a bathroom sink drain pipe. This pipe is considered an s-trap, and will siphon water out of the trap. There are two fixes for this, one being a lot easier than the other!
4. There was a leaking well water pipe in the underground enclosure. This could go unnoticed for a long time if not checked regularly!
Thanks for looking!