Why let a little thing like an electrical outlet get in the way of your trimwork.
04/11/2019

Why let a little thing like an electrical outlet get in the way of your trimwork.

Time to clean the gutters.
02/05/2019

Time to clean the gutters.

01/20/2019

Just a reminder to replace media air filters every 6 months not every 6 years.

Ahhh!…Another bootleg ground. I’m finding these way too often in older remodeled houses.
08/02/2018

Ahhh!…Another bootleg ground. I’m finding these way too often in older remodeled houses.

Installing a bootleg ground or false ground is a way to trick a standard receptacle tester into showing that the plug is properly wired. This little trick creates…

The electrical service wire on the left has seen better days.  The wire sheathing is deteriorated and copper wire is now...
08/01/2018

The electrical service wire on the left has seen better days. The wire sheathing is deteriorated and copper wire is now discolored to black from the excessive heat at the connection.

Ahh...this is the “fornes” breaker not be confused with the furnace.
07/24/2018

Ahh...this is the “fornes” breaker not be confused with the furnace.

Squirrel 1 Roof flashing 0
07/12/2018

Squirrel 1
Roof flashing 0

Watch your step...
06/25/2018

Watch your step...

I guess it’s labeled accurately as long as you can figure out what it means. 😀
06/18/2018

I guess it’s labeled accurately as long as you can figure out what it means. 😀

Here’s a good example of what thermal imaging can show you. The electrical service wires have damage sheathing from over...
06/18/2018

Here’s a good example of what thermal imaging can show you. The electrical service wires have damage sheathing from overheating but there’s no way to tell if this was caused previously or is an ongoing issue just by looking at the wires alone. The thermal imager allow us to see that the wires are over 300° and that this is an ongoing issue.

Check out my short video on why GFCI’s can keep you from getting shocked 😉⚡️
10/23/2017

Check out my short video on why GFCI’s can keep you from getting shocked 😉⚡️

Here's a short video on how I "Almost got electrocuted" a bit of a stretch but check out the video to find out what happened. You can find out more…

Address

401 N Carroll Avenue, Ste 173
Southlake, TX
76092

Opening Hours

Monday 8am - 5pm
Tuesday 8am - 5pm
Wednesday 8am - 5pm
Thursday 8am - 5pm
Friday 8am - 5pm
Saturday 8am - 5pm

Telephone

+18177819221

Alerts

Be the first to know and let us send you an email when Platinum Home Inspections posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share

Category