🔎 Does this look normal to you?
At first glance, it might just look like a standard extraction duct exiting through the roof via a tile vent.
But look a little closer… 👀
The roofing felt around the duct has been cut incorrectly and turned into the roof space.
The felt should be folded away from the loft space and back towards the roof tiles. This creates a neater detail that helps catch any condensation or water ingress and encourages it to run down the roof felt and away from the roof space.
It might look like a small detail, but this is exactly the type of defect that can be easy to miss if you don’t know what you’re looking for.
🏠 This is why a thorough new build snagging inspection is about much more than obvious cosmetic defects. It’s about identifying details that could potentially cause problems further down the line.